FK’s UCS201 insert has bore 12 mm, outside diameter 40 mm and inner-ring width B 27.4 mm. Its catalogue also lists outer-ring width C 14 mm and unequal axial lengths S 11.5/S1 15.9 mm. These are insert interfaces, not housing bolt spacing or a complete mounted-unit envelope.
Bearing units
UCS201
UCS201 is a bearing units designation documented on BearingIndex from 1 manufacturer publication. The published boundary dimensions are 12 × 40 × 27.4 mm. The publishing works are in Fujian province, China. Every value below comes from that manufacturer’s own published material, with the date it was recorded.
Match the 12 mm insert and its M5×0.8 interface before retaining the housing.
FK’s exact UCS201 publication gives a 12 mm bore, 40 mm outside diameter and 27.4 mm inner-ring width. Its UCS201-8 has a 1/2-inch bore and a different thread designation; its UC201 has the same 12 mm bore but a larger outside diameter and width. The UCS201 drawing also separates a 14 mm outer-ring width from unequal 11.5/15.9 mm axial lengths. These details matter when reusing a housing and nearby shaft hardware.
The 201 number does not preserve the bore, thread or housing seat.
A half-inch shaft is 12.7 mm, not 12 mm. That 0.7 mm nominal difference does not specify an allowable fit, or authorise alteration of the shaft or bore. If the original insert marking is missing, identify the shaft’s actual drawing and measurement requirement before choosing the suffix.
The locking interface changes too: M5×0.8 and 10-32UNF are different thread specifications. Do not transfer a metric screw assumption to a quoted UCS201-8 merely because its listed outside dimensions are near the metric insert’s dimensions. Obtain the offered locking components and instructions, including the specified tool and tightening procedure; the table’s ds entry alone provides no tightening torque.
For a retained housing, UC201 is a clearer dimensional rejection: it shares the 12 mm nominal bore but lists outside diameter 47 mm and B 31 mm, compared with UCS201’s 40 mm and B 27.4 mm. Do not order UC201 from the shared “201” ending. Have FK confirm the actual insert-to-housing seating geometry and tolerances before accepting any replacement; the outer diameter alone does not release that interface.
B 27.4 mm does not mean a centred 27.4 mm housing seat.
FK links the same UC2 section drawing and catalogue [3] from the UCS201 publication. The drawing distinguishes inner-ring width B from outer-ring width C and marks S/S1 on opposite sides of the section’s reference line. Use the exact UCS201 row to attach values to those symbols.
UCS201 field
Published metric entry [1–3]
Check on the retained assembly
B / C
27.4 / 14 mm
Inner-ring faces and outer-ring seat are different axial surfaces.
S / S1
11.5 / 15.9 mm
Keep the drawing’s labelled sides; inspect adjacent shoulders, collars and locking access in the proposed orientation.
G / F
4 / 3.7 mm
Retain these source symbols on the supplier drawing rather than relabelling either value as screw torque or tool size.
Dynamic / static load rating
9600 / 4600 N
The UCS201 insert record, rather than a housing/fastener combination’s allowable installed load.
S 11.5 plus S1 15.9 equals the listed B 27.4 mm, but the two sides are unequal. Treating the inner ring as centred from B alone hides that orientation question. This sum is dimensional bookkeeping, not endplay, internal clearance or permission to reposition the ring in the housing. Mark the actual installed side and surrounding hardware on the enquiry drawing.
FK places UCS201 under Insert Bearings. Its 0.12 kg catalogue mass and load ratings belong to that insert record; the page supplies no housing code, bolt pattern or complete-unit mass. If the requirement is a complete mounted unit, specify the housing and supplied accessories as well. This directory’s broader bearing-units category does not establish that a housing is included.
The catalogue’s UC2 illustration labels SL dual seal as standard and L3/F forms as optional. These are family options, rather than evidence that every illustrated option is supplied with this particular quotation. The examined UCS201 Feature and Option tabs contain no further visible part-specific definition. Ask FK to identify the selected sealing, lubrication and locking arrangement in the complete offer; do not infer a delivered seal from the series drawing.
The directory records dynamic 9.6 kN and static 4.6 kN; those are unit conversions of the source’s 9600 N and 4600 N. They are not two additional tests and do not approve the retained housing, locking screws or actual load direction. A replacement review needs the exact insert, its housing interface and the duty assessed together.
What each manufacturer published.
Manufacturer
Bore (mm)
Outside diameter (mm)
Inner-ring width B (mm)
Dynamic load rating (kN)
Static load rating (kN)
Source recorded
FK UCS201 FK lists UCS201 under Insert Bearings. This record describes the insert, rather than a complete housing-and-bearing unit.
A dash means the site’s recorded data does not provide that value; it is not proof that the manufacturer has never published it. Check the reviewed source notes for any newer findings.
FK publishes insert bearings, housings and mounted arrangements. Its UCS201 table separates the 12 mm metric insert from the half-inch bore and UNF-thread version; specify the complete insert-and-housing configuration and application package for the order.
Published ranges: Housed bearing units and inserts · Agricultural bearings and agri hubs · Plummer blocks and housings · Air-handling bearing units
1 designation documented here · 1 reviewed evidence record · source recorded 2026-10-08
UCS201 insert: d 12/D 40/B 27.4/C 14/S 11.5/S1 15.9/G 4/F 3.7 mm, ds M5×0.8, dynamic/static 9600/4600 N and mass 0.12 kg. The page supplies no additional visible selected configuration in its Feature/Option tabs.
Separate metric/inch records: UCS201-8 has a 1/2-inch bore and 10-32UNF thread; UC201 has a 12 mm bore but 47 mm outside diameter and 31 mm inner-ring width. The table does not establish replacement approval.
Single-page catalogue with metric/inch row groups, B/C and asymmetric S/S1 interfaces, G/F/ds symbols; family UC2/UC2-G2/CUC2 and SL/L3/F seal drawings do not identify the complete supplied UCS201 offer or housing.
Guide checked 2026-10-09. Manufacturer statements, technical background and BearingIndex purchasing suggestions are distinguished in the text. This is not application approval or firsthand product testing.