LM12S has a central R profile; LM12M has B/W locking-groove callouts. The original dimension table does not explicitly print its unit. The historical 12 × 21 × 25 mm interpretation is retained in the directory with that limitation.
Linear bearings
LM12S
LM12S is a linear bearings designation documented on BearingIndex from 1 manufacturer publication. Hengli lists the short-type length as 25 versus LM12M’s 47. Their bore/outside-diameter numbers match, but their retaining profiles and ratings differ; the comparison below explains the replacement decision. The publishing works are in Zhejiang province, China. The historical record is retained; the individually reviewed guide identifies the unresolved source fields.
Replacing LM12M with LM12S saves bearing length, but changes both the fixing interface and the load rating.
For a compact redesign, Hengli’s LM12S is worth examining: its published length number is 25 rather than LM12M’s 47, and its weight is 28.6 g rather than 54 g. The same bore and outside-diameter numbers do not make it a drop-in replacement. The short type has a different outer profile and half the published dynamic rating. Start with the housing’s actual retaining arrangement, then check the load on the shortened design.
Check what locates the bearing before changing its length.
LM12S is a candidate for a shorter housing, not a confirmed replacement in an unchanged LM12M seat. Hengli’s short-type drawing [1] and middle-type drawing [3] show why: both rows give dr 12 and D 21, but the middle type has B/W locking-groove callouts; the short type shows a central R profile. A bore match answers only the radial-size question. It does not tell you whether the existing retainers can locate the shorter bearing axially.
Part of the replacement decision
LM12S
LM12M
Published dr / D numbers
12 / 21
12 / 21
Published length L
25
47
Outer retention profile
Central R 1.2; D1 20.2
Locking-groove B 32.6; D1 20; sketch also marks W
Bearing weight
28.6 g
54 g
The geometry entries are the manufacturers’ source numbers. The tables do not explicitly print a dimension unit; the directory’s historical mm interpretation is not a released machining specification. The weights are explicitly in grams.
Find the old axial stop. Look at the housing section, not just its bore: does a shoulder, end plate or retaining component hold the LM12M? If the old hardware relies on the middle-type B/W grooves, the short drawing does not establish that it can be reused.
Draw the shorter bearing at its intended location. Keep the existing mating-part drawing beside the LM12S drawing. Mark the actual contact faces and retaining parts. A shorter part leaves more unoccupied length in an unchanged seat; decide how the selected fixing arrangement will locate it rather than relying on the old seat length.
Check the space you actually gain. The two published L numbers differ by 22, about 47% of LM12M’s length. That is a bearing-length reduction, not an automatic increase in machine travel: the shaft ends, moving block and end stops still define the available stroke. Use the approved dimensional drawing to check the whole assembly.
For a new compact housing, this comparison gives a clear starting point: design around the short type’s own profile. For a repair that must retain the old LM12M housing and retainers, keep the replacement unapproved until that interface is resolved. Do not write B 32.6 into an LM12S order merely because it appeared on the old bearing’s row.
The 25.4 g weight saving comes with a lower published load rating.
The weight difference is 54 − 28.6 = 25.4 g per bearing. This only reduces moving mass if the bearing moves with the carriage; a bearing fixed to the machine frame does not contribute that saving to moving mass. It also says nothing about a redesigned housing’s weight. These are assembly distinctions, not extra manufacturer specifications.
For load selection, compare the exact two Hengli rows, not the number of ball circuits. Both have four ball rows. LM12S nevertheless lists C 32 kgf and C0 41 kgf; LM12M lists C 64 kgf and C0 83 kgf. LM12S therefore has 50% of the middle type’s published dynamic rating and about 49% of its static rating. The common bore, outside diameter and row count do not preserve the old rating.
Keep the existing duty and change the selected bearing rating in the assessment. If shortening the housing also moves the bearing locations, update the load distribution as well. Do not retain an old LM12M calculation and change only the part number. In particular, 32 kgf is a basic dynamic bearing rating; it is not permission to put a 32 kg payload on the complete carriage.
When the assessment uses newtons, the LM12S ratings convert to approximately 314 N dynamic and 402 N static, using 1 kgf = 9.80665 N. Hengli’s life discussion [4] uses C and working load P in the same force unit. Keep both in kgf or both in N; entering 32 for C while entering a load in newtons would give the wrong ratio. The handbook also distinguishes load direction relative to the ball circuits, so the comparison above does not release a service-life prediction for an unassessed axis.
Decision: choose LM12S for further assessment when the shorter bearing solves a real packaging problem and its own fixing arrangement and lower ratings fit the revised assembly. If you only need to repair an unchanged LM12M installation, the shared dr/D numbers alone provide no reason to accept the short type as a substitute.
A dash means the site’s recorded data does not provide that value; it is not proof that the manufacturer has never published it. Check the reviewed source notes for any newer findings.
Hengli publishes standard, clearance-adjustable, open and short linear ball bearings, along with shafts and support products. Its original tables use kgf load ratings and distinguish the mounting geometry of each construction. Specify the bearing, shaft, housing and installed motion requirements together.
Published ranges: Linear-motion ball bearings · Related linear-motion bearing products
15 designations documented here · 1 reviewed evidence record · source recorded 2026-10-08
PDF page 11, printed 9/10: C and working load P in N; load direction relative to ball circuits. Used for force-unit interpretation, without a calculated life for this installation.
Guide checked 2026-10-09. Manufacturer statements, technical background and BearingIndex purchasing suggestions are distinguished in the text. This is not application approval or firsthand product testing.
We use cookies and analytics to operate this website and measure visits. Form contents and private workspace pages are excluded from analytics. Privacy & cookies