Boundary dimensions · schematic, not a product photograph or manufacturing drawing.
Linear bearings
LM5L
LM5L is a linear bearings designation documented on BearingIndex from 1 manufacturer publication. The published boundary dimensions are 5 × 10 × 28 mm. The publishing works are in Zhejiang province, China. Every value below comes from that manufacturer’s own published material, with the date it was recorded.
If an LM5L becomes stiff after housing installation, what should be checked first?
This is a troubleshooting scenario, not a diagnosis of your machine. YTP’s LM5L is a 5 mm-shaft, 10 mm-OD, 28 mm-long unsealed bearing. Establish when resistance appears and inspect the long housing and retention interfaces before treating its catalogue load rating as an answer.
Record the stage and travel position at which resistance changes.
Compare observations before housing installation, after housing installation and after the housing is fastened into the assembly, using the supplier’s safe inspection method. Record whether the symptom follows the bearing’s position on the shaft or appears when the support is fixed. These observations narrow the question; they do not prove a damaged bearing, a bent shaft or an incorrect fit.
YTP’s mounting guidance [2] requires attention to mating surfaces and alignment, warns against hammering and direct set-screw pressure on the outside shell, and warns against excessive adjustment. If the symptom starts at one of those operations, record that operation and the affected dimensions. Do not force the 5 mm shaft through a stiff assembly or change its diameter to make the symptom disappear.
Request the selected LM5L housing/shaft limits and permitted installed clearance before altering parts. Neither the product row nor the examined guidance supplies a numerical fit or preload for this specific assembly.
B = 20.4 mm is a retaining-groove field, not the bearing length.
YTP’s LM5L row [1] identifies L = 28 mm and B = 20.4 mm under the external stopping-groove heading. A housing designed around B as the total bearing length would be working from the wrong field.
Interface
YTP row
Information to return with the symptom
Shaft passage
dr 5 mm; 0/−0.010 mm
Actual shaft limits and measured positions associated with the resistance.
Housing seat
D 10 mm; 0/−0.011 mm; L 28 mm; 0/−0.30 mm
Housing bore measurements along the supported length and the fastening arrangement.
Retention
B 20.4 mm; 0/−0.30 mm; D1 9.6 mm; W 1.1 mm
Controlled groove/retaining-part drawing and the surfaces loaded by the chosen fixing method.
The bearing deviations above are not tolerances for machining the shaft and housing. Use YTP’s selected mounting specification for that purpose. The row also gives maximum radial runout 0.01 mm; it does not promise 0.01 mm positioning accuracy for the installed axis.
The kgf ratings do not explain installation resistance.
YTP lists four ball circuits, 11 g mass and C/C0 = 26.1/41.2 kgf. Preserve that force unit: these are not 26.1/41.2 kN and not a stated payload in kilograms for your carriage. The assembly’s load direction, offsets and support arrangement still need assessment.
The same table lists LMUW5-N and LMC11-d5 as publisher cross-references. Those references do not establish that another brand’s fits, seals or mounting instructions solve the symptom. Keep the investigation tied to the actual supplied LM5L and its housing drawing.
The family heading explicitly says unsealed long type. If the old part has seals, confirm the complete old designation and the proposed sealed variant instead of adding seals to this bare LM5L description. Closure friction and dimensions must come from that offered construction, not from this unsealed row.
A dash means the site’s recorded data does not provide that value; it is not proof that the manufacturer has never published it. Check the reviewed source notes for any newer findings. Dimensions every source agrees on are shown above rather than repeated per row.
Calculated from the published values.
Figure
How it is obtained
Result
Radial section height
(D − d) / 2
2.5 mm
Mean diameter dm
(D + d) / 2
7.5 mm
Arithmetic on the figures above — not a bearing life calculation for your load case.
YTP offers a linear-motion catalogue, cross-reference table and selection interface. The LM20UU/MX length difference and explicit reference-only MX sizes show why a replacement needs full interfaces and availability confirmation; qualify the shaft, alignment, load distribution and lubrication together, then reconcile calculation assumptions and applicable standard editions.
Published ranges: Standard and flanged linear ball bearings · Nickel-plated and steel-cage variants · Boxed linear-bearing units · KH drawn-cup linear bearings
287 designations documented here · 1 reviewed evidence record · source recorded 2026-10-08
Application areas each manufacturer states for its own range. Confirm load, speed, temperature and lubrication for your case.
Fields absent from the recorded dataset.
Precision class · Internal clearance · Sealing · Material · Cage material · Z class · V class · Dynamic load rating · Static load rating · Limiting speed · Lubrication · Operating temperature · Precision standard · Ring material · Rolling element material · Limiting speed — grease · Limiting speed — oil · Noise / vibration test method · Manufacturer series · Manufacturer suffix · Ball count · Ball diameter.
Ask the manufacturer for these when you enquire.
Request a quote for LM5L.
Tick the works you want above, then send one enquiry — each manufacturer answers you separately and cannot see the others.
Actual LM5L row, retaining-groove columns, 11 g mass, four circuits, kgf ratings and publisher cross-reference columns. Reference columns are not independent substitution approval.
Manufacturer mounting and alignment precautions. No exact LM5L housing fit, installed-play limit, travel speed or life established.
Guide checked 2026-10-08. Manufacturer statements, technical background and BearingIndex purchasing suggestions are distinguished in the text. This is not application approval or firsthand product testing.
We use cookies and analytics to operate this website and measure visits. Form contents and private workspace pages are excluded from analytics. Privacy & cookies