BearingIndex
THE BEARINGINDEX DIRECTORY

UCF202

15 mm SHAFT / HOUSING UNIT PENDINGUNIT UNCONFIRMED

MBF’s UCF202 shaft is explicitly 15 mm. Its housing group lists L 86 and J 64 without a separate dimension-unit heading. The historical mm interpretation is retained as unconfirmed; it is not a verified 15/86/64 radial-bearing envelope.

Bearing units

UCF202

UCF202 is a bearing units designation documented on BearingIndex from 1 manufacturer publication. The publishing works are in Hebei province, China. The historical record is retained; the individually reviewed guide identifies the unresolved source fields.

Shaft d
15 mm
Housing L
86 unit unconfirmed

Compare the 1 publication

MODEL-SPECIFIC BUYER GUIDE · SOURCES CHECKED 2026-10-09

A 15 mm shaft match does not settle the four mounting-hole positions.

MBF lists UCF202 for a 15 mm shaft, with housing-group entries L 86 and J 64. SKF FY 15 TF also takes a 15 mm shaft, but its published mounting pitch is 54 mm. SKF FYJ 20 TF has 64 mm pitch and a 20 mm bore. Use both interfaces when comparing a replacement; a matching shaft or one familiar housing number cannot settle the whole unit. MBF’s housing-group unit remains unconfirmed in the examined publication.

FY 15 TF and FYJ 20 TF answer different parts of the replacement question.

The MBF UCF202 group [1] places 15 in the shaft column headed mm. The SKF FY 15 TF row [2] also specifies d 15 mm, but gives J 54 mm and L 76 mm. The SKF front view identifies J as the hole-centre pitch and L as the housing outline; those are separate interfaces from the shaft bore.

Worked mounting example: suppose the retained plate has been measured as a 64 × 64 mm square hole-centre pattern, centred on the 15 mm shaft. That is an example input, not a measurement of your machine or confirmation of the unit missing from MBF’s housing table.

Same-axis hole-centre comparison: assumed 64 mm plate pattern and SKF FY 15 TF, 54 mm pattern. Each coordinate differs by 5 mm; symbols are not actual hole diameters.

Hole-centre comparison only. This is a calculated illustration, not a manufacturing drawing or clearance check.

With the axis and orientation held fixed, the pitch difference is 64 − 54 = 10 mm. Each SKF hole centre is therefore 5 mm inward horizontally and 5 mm inward vertically from the corresponding example plate hole. Those are coordinate differences; they are not an approved slot length, hole enlargement or bolt clearance.

A 15 mm FY 15 TF bore therefore matches the example shaft diameter, while its nominal hole-centre pattern differs. Check the retained plate’s actual hole geometry and tolerances, plus the selected unit’s fastening and load requirements, before accepting any mounting change. Do not treat trial assembly as proof that both published interfaces match.

A 64 mm pitch entry can lead to the wrong shaft size.

The same SKF table lists FYJ 20 TF with J 64 mm and L 86 mm, but its d is 20 mm. It does not solve the retained 15 mm-shaft problem. Keeping the pitch match while silently changing the bore would select a different shaft interface. The 20 − 15 = 5 mm nominal bore difference is not an allowed fit or a reason to improvise a sleeve.

For MBF, carry the actual plate measurements onto the enquiry rather than simply repeating J 64 from the catalogue. Ask the offered UCF202 drawing to show the shaft, both mounting-pitch directions, housing outline, hole details and units. MBF’s historic L/J interpretation may guide what to measure; the examined source does not yet establish a controlled matching interface.

Three 202 shaft entries share one housing group.

MBF’s same printed group distinguishes UCF202 at 15 mm from UCF202-9 at 9/16 inch and UCF202-10 at 5/8 inch. The inch entries convert to 14.2875 mm and 15.875 mm respectively, calculated using 25.4 mm per inch. Neither is the same nominal shaft entry as 15 mm, despite the grouped housing numbers.

When retaining the 15 mm shaft, keep UCF202, 15 mm together on the order. Photograph the full old marking, measure the shaft, and state whether the offer includes the complete square unit. A quote retaining only “202” or only the housing pitch leaves a different configuration possible.

The current MBF webpage [3] states a 204–312 production range, while its linked catalogue includes 202. This establishes a catalogue record, not current availability or discontinuation. Resolve current supply of the exact 15 mm complete unit with the mounting drawing. The SKF comparisons above identify geometry to review; the inquiry below is for MBF’s listed UCF202, not SKF stock.

What each manufacturer published.

ManufacturerShaft diameter d (mm)Housing length L — source number (unit unconfirmed)Mounting pitch J — source number (unit unconfirmed)Reference mass (kg)Source recorded
MBF
UCF202
1586
Historical directory interpretation: L 86 mm. MBF’s housing-dimension group prints 86 without separately stating its unit. Retained value needs the offered drawing.
64
Historical directory interpretation: J 64 mm. The original Dimension group does not separately print a unit; confirm the unit and actual mounting-hole centres.
0.612026-09-24 source ↗Request

A dash means the site’s recorded data does not provide that value; it is not proof that the manufacturer has never published it. Check the reviewed source notes for any newer findings.

The works that publish UCF202.

MBF

Xingtai, Hebei, China

Tapered roller, ball and insert bearings

MBF publishes tapered-roller, deep-groove and housed-insert ranges. Its mounted-unit catalogue separates shaft entries from housing interfaces; confirm the complete configuration and current drawing for an order.

Published ranges: Tapered roller bearings · Deep groove ball bearings · Insert ball bearings · Bearing housings

17 designations documented here · 1 reviewed evidence record · source recorded 2026-10-08

Ask MBF about UCF202

Applications the publishing works state.

ApplicationStated by
Agricultural machineryMBF
Industrial machineryMBF

Application areas each manufacturer states for its own range. Confirm load, speed, temperature and lubrication for your case.

Request a quote for UCF202.

Tick the works you want above, then send one enquiry — each manufacturer answers you separately and cannot see the others.

Open your enquiry How sourcing works here →

Figures on this page are each manufacturer’s own published material, recorded on the dates shown. How we check sources →

PREPARE THE NEXT CONVERSATION

Turn your requirements into an enquiry.

Keep the catalogue reference and your requirements separate. Blank fields remain questions for the manufacturer.

Your entries stay in this page, are not uploaded, and reset on reload. Building or copying this brief does not send an enquiry.

Review your selected products and open the enquiry form →

Open the evidence behind the comparison.

Catalogue figures belong to the stated manufacturer and document. A recording date is not a new inspection, current quotation or confirmed stock.

  1. MBF · UCF202 source ↗

    Directory record dated 2026-09-24. Confirm the current complete designation and controlled drawing with this manufacturer.

Sources used for the individual buyer guide

  1. MBF · UCF202 square-unit group ↗

    Original printed p.8: 15 mm UCF202, 9/16 inch UCF202-9 and 5/8 inch UCF202-10; grouped L 86/J 64, bolt entry M10 and mass 0.61 kg. Housing Dimension group has no separate unit label.

  2. SKF · FY 15 TF and FYJ 20 TF mounting geometry ↗

    Printed p.178, all dimensions mm: FY 15 TF d 15/J 54/L 76 versus FYJ 20 TF d 20/J 64/L 86. Original front-view drawing identifies pitch and outline. Printed p.179 identifies FY 15 TF as FY 503 M with YAR 203/15-2F; separate SKF publication, not an MBF component specification.

  3. MBF · current mounted-bearing page ↗

    Links the original catalogue and states 204–312 for the UC/UCP/UCF/UCT/UCFC/UCFL range. Does not establish current UCF202 availability or discontinuation.

Guide checked 2026-10-09. Manufacturer statements, technical background and BearingIndex purchasing suggestions are distinguished in the text. This is not application approval or firsthand product testing.