FSM’s UCP201 catalogue separates shaft diameter d 12 mm, housing length a 127 mm and bolt spacing e 95 mm. Shaft-centre height h is 30.2 mm; overall height w is 62 mm. The series photograph is marked P208/UC208 and does not identify a UCP201 delivery.

Bearing units

UCP201

UCP201 is a bearing units designation documented on BearingIndex from 1 manufacturer publication. The publishing works are in Fujian province, China. Every value below comes from that manufacturer’s own published material, with the date it was recorded.

Shaft d
12 mm
Housing a
127 mm

Compare the 1 publication

MODEL-SPECIFIC BUYER GUIDE · SOURCES CHECKED 2026-10-09

A P201 housing does not tell you whether the shaft is 12 mm or half an inch.

Huayang’s UCP200 table pairs UCP201 with a 12 mm UC201 insert and P201 housing. It separately pairs UCP201-8 with a half-inch UC201-8 insert in the same housing code. For an existing machine, identify the shaft first, then check the 30.2 mm centre height and 95 mm bolt spacing. Installation also involves two different fastener systems: the housing bolts and the insert’s locking screws have separate recommendations.

Two inserts share P201; their bores remain different.

Huayang’s UCP200 drawing and table [1] lists the following separate designations. Keep the full assembly and insert names on a replacement enquiry.

AssemblyShaft boreInsert / housingReplacement implication
UCP20112 mmUC201 / P201Metric shaft version in this record.
UCP201-81/2 inchUC201-8 / P201Same housing code; different insert bore.

Half an inch is 12.7 mm, a nominal 0.7 mm difference from the metric bore. A housing stamped P201 therefore cannot select the insert for you. Establish the shaft specification and read the insert marking; the shared base geometry does not authorise using a half-inch insert on a 12 mm shaft, or modifying either part.

The catalogue’s first row group gives 0.63 kg for the mounted unit. That is not an insert-only mass or a load rating. If buying only UC201 to reuse a housing, state that scope and obtain the seating and retention requirements separately; if buying UCP201, identify the supplied housing, insert and accessories together.

The catalogue page’s large product photograph is marked P208 and UC208. It illustrates the family, rather than proving the dimensions or configuration of a delivered UCP201. The drawing also depicts SR and TRL seal forms without selecting one for this quotation. Ask for the actual assembly configuration instead of treating the photograph or both seal sketches as supplied options.

95 mm bolt spacing and 127 mm length leave several interfaces unchecked.

The UCP201 row attaches values to different surfaces on the series drawing [1]. In particular, shaft-centre height h and overall height w answer different questions.

Source symbolUCP201 metric entryUse in a replacement review
h / w30.2 / 62 mmShaft centreline alignment versus clearance above the base.
a / e127 / 95 mmBase envelope versus distance between mounting positions.
b / g38 / 15 mmSupport footprint and the base section shown in the drawing.
S2 / S119 / 13 mmKeep the two labelled slot references on the controlled drawing; S1 is not the shaft bore.
Bi / n31 / 12.7 mmInner-ring width and the drawing’s axial reference for surrounding hardware.

A mounting arrangement can match e 95 mm and still put the shaft at the wrong height or leave insufficient room above the housing. Check the existing shaft centreline against h 30.2 mm, and nearby covers against w 62 mm. Use Bi and n with their drawing references when checking collars and screw access; n 12.7 mm is an axial dimension, not evidence of a half-inch bore in the metric UCP201.

The table prints both 3¾ inches and 95 mm for e. Exact conversion of 3¾ inches is 95.25 mm, so these catalogue entries do not create a ±0.25 mm installation tolerance. Obtain the selected assembly’s dimensioned drawing and the actual base-hole requirements before releasing drilling or machining. The drawing’s slotted base also does not state permission to correct any amount of misalignment.

A grease fitting is drawn at 45°. Check tool access in the actual offered arrangement, but do not use the series sketch as approval of its precise installed orientation. These mounting checks are why this page does not offer replacements based only on the directory’s three recorded dimensions.

The M10 base-bolt recommendation is not the UC201 locking-screw torque.

Huayang’s UCP set-screw installation guide [2] separates shaft fit, housing bolts and inner-ring locking screws into different tables. For the metric UCP201 arrangement, the relevant entries are:

InterfacePublished recommendationScope of the entry
12 mm shafth7; maximum 0, minimum −18 μmUC/SB shaft-diameter interval greater than 10 and up to 18 mm.
Housing mounting boltM10: 17 N·m, ±10%Housing installation bolt table; the UCP201 catalogue gives M10 as the metric bolt size.
Insert locking screwM5×0.8: 3.0 N·mUC200 applicable models 201–203, with SΦ40 notation in the guide.

The installation guide gives 10-32UNF alongside M5×0.8, while the housing catalogue lists 3/8 inch alongside M10. These are separate metric/inch specifications, not identical threads. Confirm the actual supplied components and their corresponding instructions. In particular, do not apply the housing’s 17 N·m recommendation to the insert’s 3.0 N·m locking-screw entry.

For a nominal 12 mm shaft, the published 0/−18 μm recommendation corresponds arithmetically to 12.000–11.982 mm. That describes this shaft-fit recommendation, rather than the bearing bore tolerance, internal clearance or permissible wear. Have Huayang confirm its application to the selected insert and actual shaft condition before using it as a repair acceptance limit.

The guide first calls for checking base rigidity, mounting-surface flatness and shaft tolerance. It then shows inserting and positioning the unit, fastening the housing, tightening the inner-ring locking screws evenly, and turning the shaft by hand to check the installed condition. A successful hand turn does not by itself approve operating load or speed. Request the offered unit’s duty assessment separately; these two pages do not provide a UCP201-specific load or speed approval.

What each manufacturer published.

ManufacturerShaft diameter d (mm)Pillow-block housing overall length a (mm)Pillow-block mounting-hole pitch e (mm)Source recorded
FSM
UCP201
FSM’s UCP201 is a 12 mm UC201 insert in a P201 housing. The listed 127 mm length and 95 mm bolt spacing do not describe its complete mounting envelope.
12127952026-09-24 source ↗Request

A dash means the site’s recorded data does not provide that value; it is not proof that the manufacturer has never published it. Check the reviewed source notes for any newer findings.

The works that publish UCP201.

FSM

Quanzhou, Fujian, China

Housed insert bearings and bearing housings

Quanzhou Huayang publishes mounted insert-bearing units and housings. Its UCP catalogue distinguishes metric and inch bores, insert codes and housing interfaces; its installation guide separates housing bolts from inner-ring locking screws. Specify the complete unit, shaft fit and selected sealing arrangement in the enquiry.

Published ranges: Housed insert ball bearings · UCP200 pillow-block units · UCF200 flange units · Bearing housings

18 designations documented here · 1 reviewed evidence record · source recorded 2026-10-08

Ask FSM about UCP201

Applications the publishing works state.

ApplicationStated by
Agricultural machineryFSM
Food-processing machineryFSM
Packaging machineryFSM
Textile machineryFSM

Application areas each manufacturer states for its own range. Confirm load, speed, temperature and lubrication for your case.

Request a quote for UCP201.

Tick the works you want above, then send one enquiry — each manufacturer answers you separately and cannot see the others.

Open your enquiry How sourcing works here →

Figures on this page are each manufacturer’s own published material, recorded on the dates shown. How we check sources →

PREPARE THE NEXT CONVERSATION

Turn your requirements into an enquiry.

Keep the catalogue reference and your requirements separate. Blank fields remain questions for the manufacturer.

Your entries stay in this page, are not uploaded, and reset on reload. Building or copying this brief does not send an enquiry.

Review your selected products and open the enquiry form →

Open the evidence behind the comparison.

Catalogue figures belong to the stated manufacturer and document. A recording date is not a new inspection, current quotation or confirmed stock.

  1. FSM · UCP201 source ↗

    Directory record dated 2026-09-24. Confirm the current complete designation and controlled drawing with this manufacturer.

Sources used for the individual buyer guide

  1. Huayang / FSM · UCP200 assembly drawing and metric/inch table ↗

    UCP201 and UCP201-8 use distinct UC201/UC201-8 inserts with P201 housing. The table gives mounting geometry, metric/inch bolt references and 0.63 kg row-group mass. The P208/UC208 photograph and SR/TRL series sketches do not identify the offered UCP201 configuration.

  2. Huayang / FSM · UCP set-screw installation guide ↗

    Three illustrated instruction sheets distinguish shaft-fit ranges, housing-bolt torques and inner-ring locking-screw torques. The 12 mm shaft falls in the UC/SB greater-than-10/up-to-18 mm h7 row; M10 mounting bolts and UC201 locking screws have separate recommendations.

Guide checked 2026-10-09. Manufacturer statements, technical background and BearingIndex purchasing suggestions are distinguished in the text. This is not application approval or firsthand product testing.