BearingIndex
THE BEARINGINDEX DIRECTORY

UCP205

BOUNDARY DIMENSIONSUNIT / mm
Shaft d = 25 mmHousing a = 140 mmBolt pitch e = 105 mm
Pillow-block unit dimensions · schematic, not a product photograph or manufacturing drawing.
Bearing units

UCP205

UCP205 is a bearing units designation documented on BearingIndex from 1 manufacturer publication. The publishing works are in Fujian province, China. Every value below comes from that manufacturer’s own published material, with the date it was recorded.

Shaft d
25 mm
Housing a
140 mm

Compare the 1 publication

MODEL-SPECIFIC BUYER GUIDE · SOURCES CHECKED 2026-10-08

Can a 25 mm UCP205 replace the unit on a 1-inch shaft?

FSM’s UCP200 drawing lists metric 205 at 25 mm and 205-16 at 1 inch. A matching P205 housing designation or mounting-hole pattern does not remove that bore difference. Identify the shaft and complete insert marking before ordering the replacement.

Keep the metric and inch variants separate.

The actual FSM drawing and table [1] places 205-14, 205-15, metric 205 and 205-16 in the same housing group. Its shaft fields are 7/8 inch, 15/16 inch, 25 mm and 1 inch respectively. They are not four names for a single bore.

One inch converts to 25.4 mm, a 0.4 mm nominal difference from 25 mm. That calculation identifies a designation mismatch, not a permissible shaft fit. If the old shaft is specified as 1 inch, an offer marked UCP205 with a 25 mm bore needs correction or a reviewed engineering change; tightening a retaining screw does not establish a correct bore.

Read the old insert marking as well as the housing marking. If only P205 is legible, obtain the shaft specification and identify the insert; the housing code alone does not resolve the metric/inch choice. A measurement of a worn shaft also needs to be compared with its approved limits, rather than treated as the original nominal designation.

Decide whether the quote replaces the complete unit or just the insert.

FSM’s metric 205 group identifies the UC205 insert and P205 housing. The examined drawing gives h = 36.5 mm shaft centre height, a = 140 mm overall base length and e = 105 mm mounting pitch. These describe different checks: a bolt pattern that matches does not prove that the shaft centre remains aligned.

For a complete replacement unit, compare the existing base footprint, mounting slots, centre height and space around the shaft against the offered drawing. For an insert-only replacement, identify the retained housing and obtain confirmation that the offered insert, its external seating geometry and retention are the intended combination. A 25 mm bore by itself does not qualify that combination.

The series illustration shows SR and TRL seal sections, but does not establish which option the offered order includes. Ask for the quoted seal and grease construction. This source row does not give a speed or load rating with which to approve the assembled unit.

Do not apply the housing-bolt value to the insert’s retaining screws.

FSM’s UCP installation material [2] separates housing mounting bolts from the inner-ring stop/set screws. Its housing-bolt table gives 17 N·m for M10, with a ±10% table heading. A separate set-screw table groups UC201–206 at M6×1.0 and gives 4 N·m. These are two different connections and published reference entries, not interchangeable torque values.

The UCP205 catalogue group lists M10 for the housing mounting bolt. Before using either installation-table entry, have FSM confirm the actual supplied fastener, insert construction and applicable tightening conditions. Do not assign the M10 housing value to a small inner-ring screw simply because both belong to this unit.

The same manufacturer material first calls for checking support rigidity, mounting-face flatness and shaft dimensional tolerances. If the base or shaft interface is wrong, neither table is a remedy. Obtain the correct unit and mounting drawing first; retain the machine’s approved installation procedure for the work itself.

What each manufacturer published.

ManufacturerPillow-block mounting-hole pitch e (mm)Source recorded
FSM
UCP205
1052026-09-24 source ↗Request

A dash means the site’s recorded data does not provide that value; it is not proof that the manufacturer has never published it. Check the reviewed source notes for any newer findings. Dimensions every source agrees on are shown above rather than repeated per row.

The works that publish UCP205.

FSM

Quanzhou, Fujian, China

Housed insert bearings and bearing housings

Quanzhou Huayang publishes mounted insert-bearing units and housings. Its UCP catalogue distinguishes metric and inch bores, insert codes and housing interfaces; its installation guide separates housing bolts from inner-ring locking screws. Specify the complete unit, shaft fit and selected sealing arrangement in the enquiry.

Published ranges: Housed insert ball bearings · UCP200 pillow-block units · UCF200 flange units · Bearing housings

18 designations documented here · 1 reviewed evidence record · source recorded 2026-10-08

Ask FSM about UCP205

Applications the publishing works state.

ApplicationStated by
Agricultural machineryFSM
Food-processing machineryFSM
Packaging machineryFSM
Textile machineryFSM

Application areas each manufacturer states for its own range. Confirm load, speed, temperature and lubrication for your case.

Fields absent from the recorded dataset.

Precision class · Internal clearance · Sealing · Material · Cage material · Z class · V class · Dynamic load rating · Static load rating · Limiting speed · Lubrication · Operating temperature · Precision standard · Ring material · Rolling element material · Limiting speed — grease · Limiting speed — oil · Noise / vibration test method · Manufacturer series · Manufacturer suffix · Ball count · Ball diameter · Reference mass.

Ask the manufacturer for these when you enquire.

Neighbouring designations documented here.

DesignationEnvelope d × D × B (mm)Bearing familyWorks
UCP201—Bearing units1
UCP202—Bearing units1
UCP203—Bearing units1
UCP204—Bearing units1
UCP206—Bearing units1
UCP207—Bearing units1
UCP208—Bearing units1
UCP209—Bearing units1

Each envelope shown is that designation’s own published size.

Request a quote for UCP205.

Tick the works you want above, then send one enquiry — each manufacturer answers you separately and cannot see the others.

Open your enquiry How sourcing works here →

Figures on this page are each manufacturer’s own published material, recorded on the dates shown. How we check sources →

PREPARE THE NEXT CONVERSATION

Turn your requirements into an enquiry.

Keep the catalogue reference and your requirements separate. Blank fields remain questions for the manufacturer.

Your entries stay in this page, are not uploaded, and reset on reload. Building or copying this brief does not send an enquiry.

Review your selected products and open the enquiry form →

Open the evidence behind the comparison.

Catalogue figures belong to the stated manufacturer and document. A recording date is not a new inspection, current quotation or confirmed stock.

  1. FSM · UCP205 source ↗

    Directory record dated 2026-09-24. Confirm the current complete designation and controlled drawing with this manufacturer.

Sources used for the individual buyer guide

  1. FSM / Huayang · UCP200 series drawing and parameter image ↗

    Actual UCP205 group visually read: metric/inch shaft variants, UC205/P205, h/a/e and M10 housing-bolt field. Series seal illustrations do not identify the offered option; no load/speed approval established.

  2. FSM / Huayang · UCP installation and maintenance images ↗

    Three source images actually viewed: mating-interface checks, housing-bolt torque table and separate set-screw table. Values are manufacturer references; confirm actual supplied fasteners and applicable conditions before installation.

Guide checked 2026-10-08. Manufacturer statements, technical background and BearingIndex purchasing suggestions are distinguished in the text. This is not application approval or firsthand product testing.